Tests and Capabilities (Quick Reference)

The following chart identifies and describes available tests by function.

Not all the tests listed are described in this manual. This list is intended as reference only.

DMM

GMM

LS

Test

Function

 

 

a

Two Channel Lab Scope

Displays two Lab Scope channels automatically.

 

a

 

Dual Graphing Meter

Displays two Graphing Multimeter channels automatically.

 

 

a

Ignition Probe

Measures secondary Ignition voltage 2 to 50kV. Displays secondary ignition (kV) waveforms.

a

a

a

Volts DC

Measures direct current voltage. DC voltage is measured through the two test leads connected to a DC circuit.

a

a

 

Volts DC - Average

Measures DC voltage using a filter to determine the average voltage over a period in time. DC voltage is measured through the two test leads connected to a DC circuit.

a

a

 

Volts AC RMS

Measures the effective AC voltage, not the peak voltage which results in measurements with higher accuracy. The AC RMS (root mean square) voltage value can be defined as the equivalent DC voltage of the AC voltage measured. RMS values are commonly used in AC electrical measurement, as they are more representative of DC measurements.

a

a

 

Ohms

Measures electrical resistance (opposition to current) 0 to 4 M Ohms. Scope supplied DC current is passed through the circuit to measure the resistance between the two connected test leads.

a

 

 

Diode/Continuity

Measures voltage drop across a diode and continuity through a diode. Scope supplied DC current is passed through the diode to measure the voltage drop between the two connected test leads. Typical setup for positive to negative current flow - positive lead (anode +/side) and negative (cathode -/side).

 

a

 

Frequency

Measures the number of times a signal repeats itself per second. Used to measure frequency of signals such as CKP, CMP and wheel speed sensors.

 

a

 

Pulse Width

Measures the on-time of various components
(e.g. components that cycle on and off like the EGR, or canister purge).

 

a

 

Injector Pulse Width

Measures fuel injector on-time when checking for variances when engine load is changed and/or physical problems with the injector.

 

a

 

Duty Cycle

Measures the ratio of the pulse width to the complete cycle width, the on-time of components that cycle on and off like EGR, or canister purge from 0–100%.

a

a

a

Low Amps (20)

Used to measure amperage of typical devices (e.g. ignition coils, injectors, fuel pumps) that may draw up to 20A peak (startup) when initially started. Also used to measure parasitic draw.

a

a

a

Low Amps (40)

Used to measure amperage of typical motors and devices that may draw up to 40A peak (startup) when initially started.

a

a

a

Low Amps (60)

Used to measure amperage of larger motors and devices that may draw up to 60A peak (startup) when initially started.

 

a

 

MC Dwell (60)

Measures carburetor Mixture Control Solenoids (0–60°). The duty cycle of the solenoid is expressed in the dwell angle of a 6 cylinder engine: 100% = 60 deg.

 

a

 

MC Dwell (90)

Measures fuel system Mixture Control Solenoids (0–90°). The duty cycle of the solenoid is expressed in the dwell angle of a 4 cylinder engine: 100% = 90 deg.

 

a

a

100 PSI Vacuum

Used to measure vacuum up to 20 in.Hg,
using the 0–100 psi transducer.

 

a

a

100 PSI Pressure

Used to measure pressures for typical systems such as, fuel, oil, EVAP, hydraulic/transmission fluid etc. up to 100 psi, using the 0–100 psi transducer.

 

a

a

500 PSI Pressure

Used to measure pressures for typical systems such as, hydraulic/transmission fluid pressure, cylinder compression, and AC high side up to 500 psi, using the 0–500 psi transducer.

 

a

a

5000 PSI Pressure

Used to measure pressures for typical systems such as, ABS, power steering, and heavy-duty hydraulic system fluid up to 5000 psi, using the 0–5000 psi transducer.

 

a

a

MT5030 Vacuum

Used to measure vacuum up to 29 in.Hg,
using the MT5030 pressure transducer adapter.

 

a

a

MT5030 Pressure

Used to measure fluid and gas pressures up to 500 psi, using the MT5030 pressure transducer adapter.

 

a

a

EEDM506D Temperature

Used to measure temperatures from -50° to 1800° F
(-45 to 982° C), using the EEDM506D pressure transducer adapter.